Lamp Post Style CCTV Columns (LPS)

Design Specification

  • Excellent stability characteristics for minimal camera movement. 
  • A most desirable column where aesthetics are of prime importance. 
  • Suitable for all public access areas. 
  • Flange mounted FM type root. 
  • Heavy duty versions available. 
  • Pocket type roots available for restricted foundation locations. 
  • Totally concealed cable management facility. 
  • Hot dipped galvanised finish for maximum weather protection and low maintenance requirements. 
  • Custom and bespoke versions tailored to the customer's requirements.

General Specification

  • Standard pan and tilt fixing of 101.6 PCD. 
  • Inspection / jointing aperture with backboards as standard feature. 
  • Compatible with WEC adaptors, accessories and anti climbs. 
  • Heavy duty version loadings up to 25 kg. 
  • Variety of standard heights up to 10 metres* 

*See Technical Sheet for further information, please note the heights specified are nominal and may vary. 

In stock
Only %1 left
£0.00 + VAT

ADDITIONAL OPTIONS:
Clear Selection

Maximum 150 characters

*ALREADY A CUSTOMER? Contact our helpful sales team for more information.

Lamp Post CCTV Technical Specification

Lamp Post CCTV Standards Applicable
Lamp Post CCTV Base & Windload Specification

Installation Method

1. From the map, select location of installation
2. Excavate as per recommended area and depth
3. Assemble root base as shown in fig. 1
4. Insert root base into the hole ensuring that it is
level and that the four studs protrude 60-70mm
above the concrete foundation
5. Fit the cable duct if routing via the interior of the
column. A plastic pipe of approximately 100mm
outside diameter is recommended for this. Ensure
this protrudes through the template by 50mm minimum.
6. Pour concrete ensuring that it is a mix of C35
to table 6 BS 8110 and then tamp down well
7. Fit the setting template over the four protruding
studs, double-checking that they are level and that
clear access can be gained to the cable duct if it
is being used
8. Leave the concrete to cure for a minumum of 72
hours prior to attempting to erect the column
9. When fitting the column, ensure that the concrete
base is in complete contact with the underside of
the column and grout accordingly.
10. When the column has been fitted, protect the studs
with a suitable protective coating. Denzo tape or
similar is recommend for this.

Lamp Post CCTV Accessories & Adaptors
SKU
Lamp Post Style CCTV Columns (LPS)